Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
J Fr Ophtalmol ; 47(6): 104186, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38663226

ABSTRACT

PURPOSE: To compare two swept-source OCT optical biometers, the Anterion® (Heidelberg Engineering GmbH, Heidelberg, Germany) and the IOLMaster 700® (Carl Zeiss Meditec AG, Jena, Germany), in the analysis of biometric data, intraocular lens (IOL) calculation and postoperative spherical equivalent predictability. METHODS: This was a real-life, single-center, retrospective study including 152 eyes of 81 consecutive patients referred for cataract surgery. All patients were examined with the IOLMaster 700® and the Anterion®. Biometric data (axial length [AL], anterior chamber depth [ACD], mean keratometry [Km], K1 [flat keratometry], K2 [steep keratometry] and axis, TK1 [flat total keratometry], TK2 [steep total keratometry], central pachymetry, lens thickness [LT], white-to-white distance [WTW]), IOL calculation with the SRK/T formula, and postoperative refractive outcome at 1 month were compared. RESULTS: All biometric measurements were significantly different between the two biometers. Correlations were excellent for AL, pachymetry, ACD, LT and keratometry measurements, and for the IOL calculation (r>0.96, intraclass correlation coefficient=1). The IOL power for emmetropia was similar between both biometers when the SRK/T formula was used (20.84±3.24D versus 20.86±3.29D, P=0.61). The mean postoperative spherical equivalent prediction error calculated using the SRK/T formula was 0.03±0.5D for the IOLMaster 700® versus 0.01±0.47D for the Anterion® (P=0.12). CONCLUSIONS: This study showed excellent correlation and agreement for the biometric measurements and the IOL power calculation with the SRK/T formula between both biometers.

2.
J Fr Ophtalmol ; 2023 Sep 25.
Article in French | MEDLINE | ID: mdl-37758545

ABSTRACT

INTRODUCTION: Steroid-induced ocular hypertension (OHT) occurs in approximately one third of cases after dexamethasone implant (DEXi) injection. Among these, more than one fifth occur after the third DEXi intravitreal injection (IVI). Our goal was to analyze the clinical profiles of these late responders. MATERIAL AND METHODS: A real-life, retrospective, observational study was conducted to assess demographic characteristics and intraocular pressure (IOP) responses in late responders (IOP ≥ 21mmHg, n DEXi ≥ 4). The following parameters were analyzed: IOP 2 months after IVI and number of glaucoma medications needed. The IOP response compared to baseline was defined as low (< +6mmHg), moderate (≤ +15mmHg) or high (> 15mmHg). RESULTS: Late steroid-induced OHT occurred in 20.8% of cases. Twenty eyes (18 patients) were included. The mean duration of follow-up was 3.8±1.9 years. They received a mean number of 9.5±4.2 IVI. The first OHT peak, measured at 25.3±3.2mmHg (21-31), occurred after 6.8±2.3 IVI. Approximately 65% of OHT spikes occurred between the fourth and sixth IVI; 35% occurred later. At maximum, 1.7±1.0 glaucoma medications and 0.75±0.79 SLT procedures were required to control the OHT, with no filtering surgery required. The ratio of "low," "moderate," and "high" responders was 5%, 85% and 10% respectively. CONCLUSION: Late steroid-induced OHT occurs after at least 3 DEXi in one fifth of multi-injected patients, requiring long-term IOP monitoring. This case series identifies mostly moderate responder profiles, whose IOP rise often remains well-controlled with medical management or laser treatment (SLT).

6.
J Fr Ophtalmol ; 43(10): 1002-1008, 2020 Dec.
Article in French | MEDLINE | ID: mdl-33036803

ABSTRACT

PURPOSE: Descemet's membrane detachment (DMD) is a rare but potentially serious complication of cataract surgery. Although there are no consensual guidelines regarding the diagnosis or treatment of DMD, incorrect treatment may result in irreversible corneal changes with visual sequellae. The purpose of our study is to describe the diagnosis and treatment of DMD. METHODS: We report a series of 9 cases of DMD, their diagnosis, treatment and outcomes. We tested the HELP protocol retrospectively against our 9 real-life cases. RESULTS: Two cases recovered with simple medical management, 4 required air-bubble descemetopexy, and three required keratoplasty. Our study revealed that the main factor associated with poor outcomes is late diagnosis and management. CONCLUSION: Our series illustrates the importance of proactive management and timely diagnosis by performing anterior segment OCT in the setting of persistent postoperative corneal edema.


Subject(s)
Corneal Diseases/diagnosis , Corneal Diseases/etiology , Descemet Membrane/surgery , Phacoemulsification/adverse effects , Postoperative Complications/diagnosis , Aged , Aged, 80 and over , Corneal Edema/diagnosis , Corneal Edema/etiology , Corneal Injuries/diagnosis , Corneal Injuries/etiology , Descemet Membrane/injuries , Descemet Membrane/pathology , Female , Humans , Male , Middle Aged , Postoperative Complications/etiology , Retrospective Studies , Tomography, Optical Coherence
SELECTION OF CITATIONS
SEARCH DETAIL
...